EURADOS IC2019exteye- a self-funded intercomparison for extremity and eye lens dosemeters organised by EURADOS working group 2
Creators
- 1. Charthouse Data Management Limited, Unit A17 Admiralty Park, Poole BH16 6HX (United Kingdom)
- 2. Cavendish Nuclear Limited, A11 Berkeley ADS, Berkeley Centre, Berkeley, Gloucestershire GL13 9FB (United Kingdom)
- 3. CIEMAT, Radiation Dosimetry, Avda Complutense 40, 28040 Madrid (Spain)
- 4. Mirion Dosimetry Services, PO Box 60067, 6800 JB Arnhem (Netherlands)
- 5. Seibersdorf Labor GmbH, A-2444 Seibersdorf (Austria)
- 6. Mirion Technologies -AWST- GmbH, Auswertungsstelle, Otto-Hahn-Ring 6, D-81739 Munchen (Germany)
Description
The European Radiation Dosimetry Group (EURADOS) has been organising regular, self-funding, external dosimetry intercomparisons (ICs) since 2008. IC2019exteye, for extremity and eye lens dosemeters, attracted 113 systems (68 extremity and 45 eye lens) from 60 institutes with participants from 26 countries around the world. Irradiations were carried out in accredited European irradiation facilities in terms of Hp(0.07)/or Hp(3) in the ranges: photon energy: 16-662 keV, beta mean energy 250-1000 keV, dose: 0.5 mSv to 1 Sv, maximum angle of incidence: ±60 deg.. This paper describes the IC2019exteye set-up, irradiation plan and coordination with an overview of the main conclusions. Out of the total of 113 systems, 57 reported results for photons only and 56 reported both photon and beta. In general, the participants showed very satisfactory performances with the medians of all Hp(0.07) and Hp(3) response values very close to unity. (authors)
Additional details
Identifiers
- DOI
- 10.1093/rpd/ncac275;
Publishing Information
- Journal Title
- Radiation Protection Dosimetry
- Journal Volume
- 199
- Journal Issue
- 15-16
- Journal Page Range
- p. 1759-1763
- ISSN
- 0144-8420
Conference
- Title
- Joint International Conference on Individual Monitoring of Ionizing Radiation; NEUDOS-14: Neutron and Ion Dosimetry Symposium
- Acronym
- IM2022
- Dates
- 25-29 Apr 2022
- Place
- Krakow (Poland)
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- France
- INIS RN
- 55045326
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- DOSEMETERS; DOSIMETRY; INCIDENCE ANGLE; IRRADIATION; IRRADIATION PLANTS; PERFORMANCE; PHOTONS; RADIATION DOSES
- Descriptors DEC
- BOSONS; DOSES; ELEMENTARY PARTICLES; MASSLESS PARTICLES; MEASURING INSTRUMENTS; NUCLEAR FACILITIES
Optional Information
- Notes
- 11 refs.