Published 2012 | Version v1
Miscellaneous

Evaluation on decay heat removal capability of isolation condenser in Fukushima Daiichi Nuclear Plant Unit 1

  • 1. Hokkaido Univ., Sapporo, Hokkaido (Japan)

Description

In this study, we aimed to quantitatively evaluate cooling capacity of isolation condenser (IC) for core cooling in Fukushima Daiichi Nuclear Plant Unit 1. In order to evaluate cooling capacity, we calculated decay heat which was emitted from core. We used the data of nuclear fuel and rated thermal power which is released by TEPCO. Analysis was conducted with TRAC code. We made an experiment in order to check input data for IC. Because analysis data was close to experimental data, we made sure of validity of input data. We analyzed IC under conditions which were recorded when IC started up and tsunami rushed toward plant. As a result of analysis, we confirmed that cooling capacity exceed decay heat under both conditions. In conclusion, IC had a capacity to prevent core meltdown accident in Fukushima Daiichi Nuclear Plant Unit 1. (author)

Part of:
The 17th national symposium on power and energy systems (SPES 2012)

Additional details

Publishing Information

Imprint Title
The 17th national symposium on power and energy systems (SPES 2012)
Imprint Pagination
464 p.
Journal Page Range
p. 333-334

Conference

Title
17. national symposium on power and energy systems
Acronym
SPES 2012
Dates
21-22 Jun 2012
Place
Fukuoka (Japan)

Optional Information

Notes
7 refs., 6 figs., 1 tab.; This record replaces 45027398