Published October 1986
| Version v1
Journal article
Vacuum insulator with shielded dielectric surface
- 1. Institute of High-Current Electronics, Tomsk, USSR
Description
The results of a study of vacuum feedthrough insulators with metal shields on the surfaces of the insulating layers are presented. The tests were performed on an electron accelerator with an accelerating voltage of 0.5-1.8 MV, a diode current of 6-25 kA, and a voltage-pulse duration of 40-100 nsec. Optimal shield dimensions were found that provided breakdown electric-field strengths of 100-200 kV/cm averaged over the dielectric. The insulators operated as cutoff dischargers. The use of shields increased the breakdown voltage by a factor of 1.7 and considerably increased the reliability of the insulators
Additional details
Publishing Information
- Journal Title
- Instrum. Exp. Tech. (Engl. Transl.)
- Journal Volume
- 29
- Journal Issue
- 2
- Series
- Instrum. Exp. Tech. (Engl. Transl.).
- Journal Page Range
- 415-418
- ISSN
- 0020-4412
- CODEN
- INETA
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 18080261
- Subject category
- S43: PARTICLE ACCELERATORS;
- Descriptors DEI
- ACCELERATORS; BREAKDOWN; CATHODES; COMPUTER-AIDED DESIGN; DIELECTRIC MATERIALS; ELECTRIC FIELDS; ELECTRICAL INSULATORS; ELECTRON BEAMS; KEV RANGE 100-1000; MATERIALS TESTING; MEV RANGE 01-10; PERFORMANCE TESTING; SHIELDS
- Descriptors DEC
- BEAMS; ELECTRICAL EQUIPMENT; ELECTRODES; ENERGY RANGE; EQUIPMENT; KEV RANGE; LEPTON BEAMS; MATERIALS; MEV RANGE; PARTICLE BEAMS; TESTING
Optional Information
- Notes
- Translated from Prib. Tekh. Eksp.; No. 2, 138-141(Mar-Apr 1986). Cover-to-cover translation of Pribory i Tekhnika Ehksperimenta (USSR).