Efficiency calibration of airborne γ-ray spectrometer using sourceless efficiency calibration method
Creators
- 1. East China University of Technology, Jiangxi (China). School of Nuclear Science and Engineering
Description
Based on the exponential law of narrow beam γ ray and calculus principle, a numerical calculation model for sourceless efficiency calibration of airborne γ-ray spectrometer has been developed. Through experiments and simulations, it was found that the relative deviation between the efficiency of airborne γ-ray spectrometer with different surface sources and volume sources and the value of stimulation was within ± 1.5% when conducting low-attitude detection, and the relative deviation between the calculation results of infinite volume source containing 1460.8 keV or 2614.5 keV γ photons at the altitude of 90-150 m and the experimental values was 5.41-11.27%. The above experiments sufficiently proved that sourceless efficiency calibration model could be appropriate for the detection practice of airborne γ-ray spectrometry. (author)
Additional details
Publishing Information
- Journal Title
- Journal of Radioanalytical and Nuclear Chemistry
- Journal Volume
- 322
- Journal Issue
- 2
- Journal Page Range
- p. 613-619
- ISSN
- 0236-5731
- CODEN
- JRNCDM
INIS
- Country of Publication
- Hungary
- Country of Input or Organization
- Hungary
- INIS RN
- 50080887
- Subject category
- S37: INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY;
- Descriptors DEI
- CALCULATION METHODS; CALIBRATION; EFFICIENCY; ENERGY RANGE; GAMMA SPECTROSCOPY; KEV RANGE 100-1000; MEASURING METHODS
- Descriptors DEC
- ENERGY RANGE; KEV RANGE; SPECTROSCOPY
Optional Information
- Notes
- 16 refs.