Published November 2019 | Version v1
Journal article

Efficiency calibration of airborne γ-ray spectrometer using sourceless efficiency calibration method

  • 1. East China University of Technology, Jiangxi (China). School of Nuclear Science and Engineering

Description

Based on the exponential law of narrow beam γ ray and calculus principle, a numerical calculation model for sourceless efficiency calibration of airborne γ-ray spectrometer has been developed. Through experiments and simulations, it was found that the relative deviation between the efficiency of airborne γ-ray spectrometer with different surface sources and volume sources and the value of stimulation was within ± 1.5% when conducting low-attitude detection, and the relative deviation between the calculation results of infinite volume source containing 1460.8 keV or 2614.5 keV γ photons at the altitude of 90-150 m and the experimental values was 5.41-11.27%. The above experiments sufficiently proved that sourceless efficiency calibration model could be appropriate for the detection practice of airborne γ-ray spectrometry. (author)

Additional details

Publishing Information

Journal Title
Journal of Radioanalytical and Nuclear Chemistry
Journal Volume
322
Journal Issue
2
Journal Page Range
p. 613-619
ISSN
0236-5731
CODEN
JRNCDM

INIS

Country of Publication
Hungary
Country of Input or Organization
Hungary
INIS RN
50080887
Subject category
S37: INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY;
Descriptors DEI
CALCULATION METHODS; CALIBRATION; EFFICIENCY; ENERGY RANGE; GAMMA SPECTROSCOPY; KEV RANGE 100-1000; MEASURING METHODS
Descriptors DEC
ENERGY RANGE; KEV RANGE; SPECTROSCOPY

Optional Information

Notes
16 refs.