Published 1986 | Version v1
Journal article

Energy response of hot-pressed thin layer detectors to photon and electron irradiations

  • 1. Physikalisch-Technische Bundesanstalt - Inst. Berlin (Germany, F.R.)
  • 2. Physikalisch-Technische Bundesanstalt, Braunschweig (Germany, F.R.)
  • 3. CEA Centre d'Etudes Nucleaires de Fontenay-aux-Roses, 92 (France)
  • 4. Giessen Univ. (Germany, F.R.). 1. Physikalisches Inst.

Description

Hot pressed thin layer detectors for integrating solid state dosemeters (C/B/Al2O3/LiF:Mg,Ti and Al/Al2O3/LiF:Na,Mg, Ti structures) were investigated with respect to sensitivity for X and γ irradiations with different energies (6 keV -1 MeV) and variable radiation incidence (+ - 600 isotropy) with and without the presence of phantoms. TL and TSEE readouts showed characteristic over-and under-estimations of the applied doses. The TL response of the new detectors to β irradiations (90Sr-90Y, 204Tl, 147Pm) meets the requirements of practice by decreasing only for the low energy electron source. (author)

Additional details

Publishing Information

Journal Title
Radiat. Prot. Dosim.
Journal Volume
17
Journal Issue
1-4
Series
Radiat. Prot. Dosim.
Journal Page Range
71-75
ISSN
0144-8420
CODEN
RPDOD

Conference

Title
8. international conference on solid state dosimetry.
Dates
26-29 Aug 1986.
Place