Published December 1983
| Version v1
Report
Open
Personnel doses on the handling of 99Tc(sup)m at hospitals
Description
The absorbed whole-body dose to the personnel working full time with nuclear medicine investigations in vivo is found to be 1-4 m Gy/a, as measured on the film badge and corresponding to a dose equivalent of 0.7 to 2.8 m Sv. The patient is contributing 1 to 2 m Gy. The absorbed dose to the fingers of the personnel easily exceeds 500 m Sv/a emanating from the syringes and bottles. The injection of patients renders the highest exposures. If rubber gloves were not used the contamination from 1 kBq 99Tc(sub)m will be 0.5 Gy/h-1 to the skin. Latex rubber gloves will provide sufficient protection when used less than for 30 minutes. (G.B.)
Availability note (English)
MF available from INIS under the Report Number.Files
15043873.pdf
Files
(621.4 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:97330f2fcc0bfe24e984d319c71b139a
|
621.4 kB | Preview Download |
Additional details
Additional titles
- Original title (Swedish)
- Personaldoser vid hantering av
Publishing Information
- Imprint Pagination
- 40 p.
- Report number
- SSI-a--83-18
INIS
- Country of Publication
- Sweden
- Country of Input or Organization
- Sweden
- INIS RN
- 15043873
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Descriptors DEI
- CONTAMINATION; DOSE EQUIVALENTS; GLOVES; HOSPITALS; NUCLEAR MEDICINE; PERSONNEL; RADIATION DOSES; RADIONUCLIDE ADMINISTRATION; SKIN; TECHNETIUM 99
- Descriptors DEC
- BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; BODY; BUILDINGS; CLOTHING; HOURS LIVING RADIOISOTOPES; INTERMEDIATE MASS NUCLEI; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; MEDICAL ESTABLISHMENTS; MEDICINE; NUCLEI; ODD-EVEN NUCLEI; ORGANS; PROTECTIVE CLOTHING; RADIOISOTOPES; TECHNETIUM ISOTOPES; YEARS LIVING RADIOISOTOPES
Optional Information
- Notes
- 19 refs.