Published December 1983 | Version v1
Report Open

Personnel doses on the handling of 99Tc(sup)m at hospitals

Description

The absorbed whole-body dose to the personnel working full time with nuclear medicine investigations in vivo is found to be 1-4 m Gy/a, as measured on the film badge and corresponding to a dose equivalent of 0.7 to 2.8 m Sv. The patient is contributing 1 to 2 m Gy. The absorbed dose to the fingers of the personnel easily exceeds 500 m Sv/a emanating from the syringes and bottles. The injection of patients renders the highest exposures. If rubber gloves were not used the contamination from 1 kBq 99Tc(sub)m will be 0.5 Gy/h-1 to the skin. Latex rubber gloves will provide sufficient protection when used less than for 30 minutes. (G.B.)

Availability note (English)

MF available from INIS under the Report Number.

Files

15043873.pdf

Files (621.4 kB)

Name Size Download all
md5:97330f2fcc0bfe24e984d319c71b139a
621.4 kB Preview Download

Additional details

Additional titles

Original title (Swedish)
Personaldoser vid hantering av

Publishing Information

Imprint Pagination
40 p.
Report number
SSI-a--83-18

Optional Information

Notes
19 refs.