Description

A preproduction intermediate heat exchanger (IHX) for the SNR 300 was tested at full scale in the TNO--CTI 50 MW sodium component test facility. After some preliminary tests and after conducting a complete test program there was a demand for internal inspection that would not involve cutting operations. The answer to this problem was through shell radiography. Radiography is of course a well known technique, however, in this case the results were much better than what was expected. Therefore this type of non destructive testing warrants some explanation

Files

33015413.pdf

Files (98.0 kB)

Name Size Download all
md5:a71b32de23e37ada795cc041f95aeaae
98.0 kB Preview Download
Part of:
Specialists' meeting on in-service inspection and monitoring of LMFBRs. Summary report

Additional details

Publishing Information

Imprint Title
Specialists' meeting on in-service inspection and monitoring of LMFBRs. Summary report
Imprint Pagination
212 p.
Journal Page Range
p. 205-207
Report number
IWGFR--35

Conference

Title
IAEA-IWGFR specialists' meeting on in-service inspection and monitoring of LMFBRs
Dates
20-22 May 1980
Place
Bensberg (Germany)

Optional Information

Notes
2 figs