Published 1994 | Version v1
Report Open

Preliminary assessment of pump IST effectiveness

Description

A preliminary review of Inservice Testing (IST) effectiveness for Code Class 1, 2, and 3 pumps at nuclear power plants was performed. IST requirements are specified by ASME Section XI, and the Operations and Maintenance Standard (OM Part 6). The INPO NPRDS database was used to provide failure reports for these components for 1988 to 1992. This time frame coincides with the issuance of Generic Letter 89-04, which resulted in a more consistent application of the requirements by the licensees. For this time period, 2585 pump failures were reported. A review of these failures indicated that the majority (71.6%) were due to external leakage, and were excluded from this study since these events typically do not affect pump operability and are not detected by the measurement of IST parameters. Of the remaining 733 events, a review was performed to identify the primary failure causes, failure modes, and method of detection. Plant testing programs, consisting of IST, surveillance testing, and special testing, detected approximately 40% of these occurrences. Others were detected through operational abnormalities, routine and incidental observations, alarms, and while performing maintenance. This paper provides a discussion of the results of the study

Availability note (English)

MF available from INIS under the Report Number; Also available from OSTI as DE94013019; NTIS; US Govt. Printing Office Dep.

Files

25073849.pdf

Files (489.4 kB)

Name Size Download all
md5:9e639f1db6c38a6453022d44440f7e29
489.4 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
17 p.
Report number
BNL-NUREG--60270

Conference

Title
3. ASME/NRC symposium on valve and pump testing.
Dates
18-21 Jul 1994.
Place
Washington, DC (United States).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
25073849
Subject category
S22: GENERAL STUDIES OF NUCLEAR REACTORS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
FAILURES; IN-SERVICE INSPECTION; MAINTENANCE; MECHANICAL VIBRATIONS; NUCLEAR POWER PLANTS; PUMPS; STANDARDS; TESTING; VALVES
Descriptors DEC
CONTROL EQUIPMENT; EQUIPMENT; FLOW REGULATORS; INSPECTION; NUCLEAR FACILITIES; POWER PLANTS; THERMAL POWER PLANTS

Optional Information

Contract/Grant/Project number
Contract AC02-76CH00016
Funding organization
Nuclear Regulatory Commission, Washington, DC (United States).
Secondary number(s)
CONF-940774--3.