Published December 1992 | Version v1
Report Restricted

The D0 calorimeter trigger

  • 1. Brookhaven National Lab., Upton, NY (United States)

Description

The D0 calorimeter trigger system consists of many levels to make physics motivated trigger decisions. The Level-1 trigger uses hardware techniques to reduce the trigger rate from ∼ 100kHz to 200Hz. It forms sums of electromagnetic and hadronic energy, globally and in towers, along with finding the missing transverse energy. A minimum energy is set on these energy sums to pass the event. The Level-2 trigger is a set of software filters, operating in a parallel-processing microvax farm which further reduces the trigger rate to a few Hertz. These filters will reject events which lack electron candidates, jet candidates, or missing transverse energy in the event. The performance of these triggers during the early running of the D0 detector will also be discussed

Availability note (English)

MF available from INIS under the Report Number; OSTI as DE93006838; NTIS; INIS; US Govt. Printing Office Dep.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
8 p.
Report number
FNAL/C--92/370

Conference

Title
3. international conference on calorimetry in high energy physics.
Dates
29 Sep - 2 Oct 1992.
Place
Corpus Christi, TX (United States).

Optional Information