Published November 2002 | Version v1
Journal article

ITER primary first wall mock-up fabrication and testing for Be/Cu alloy joining development

Description

This paper presents the main results obtained so far from the development work performed in Europe to define the joining conditions between beryllium (Be) tiles and the dispersion strengthened copper alloy (DS-Cu) heat sink material for the ITER primary first wall (PFW). Two Be/DS-Cu joining techniques were investigated: hot isostatic pressing and furnace brazing. Six PFW mock-ups have been thermal fatigue tested so far. One PFW mock-up with HIPped Be tile was tested at 2.5 MW/m2 for 1000 cycles without any indication of failure. On two other mock-ups, Be tiles detached at or above 2.7 MW/m2. Two others were tested at 0.7 MW/m2 for 13000 cycles also without any indication of failures. A first PFW mock-up with a furnace brazed Be tile was tested at 1.6 MW/m2 for 1000 cycles. These results should be compared with the operation conditions of the ITER PFW, namely 0.5 MW/m2 peak heat flux and off-normal events up to 1.4 MW/m2. Thermal fatigue testing of other mock-ups is still in progress and the development programme is continuing to further increase the engineering margins while decreasing the fabrication cost of the PFW panels

Additional details

Identifiers

PII
S092037960200100X;

Publishing Information

Journal Title
Fusion Engineering and Design
Journal Volume
61-62
Journal Issue
3
Journal Page Range
p. 643-648
ISSN
0920-3796
CODEN
FEDEEE

Optional Information

Copyright
Copyright (c) 2002 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.