Published August 1993 | Version v1
Report

A design aimed at increasing the pressurizer earthquake resistance at the Mochovce nuclear power plant, and a sensitivity modal analysis

Description

Seismic calculations were performed for loop No. 1 of the primary coolant circuit at unit 1 of the Mochovce nuclear power plant; the effect was considered of increased earthquake resistance of the two pressurizer pipelines by the use of viscous dampers. In order to gain insight into the seismic response of all safety-related pipe systems, sensitivity analysis was carried out based on a gradual simplification of the complex computation model, and the response of the individual separate pipe systems was determined and compared with the complex model. 20 tabs., 6 figs., 7 refs

Availability note (English)

Available from Ustav Jaderneho Vyzkumu, 252 68 Rez u Prahy, Czech Republic.

Additional details

Additional titles

Original title (Czech)
Navrh seismickeho zodolneni potrubi kompenzatoru objemu EMO a citlivostni modalni analyza

Publishing Information

Imprint Pagination
49 p.
Report number
UJV--9985 T