Published November 1988
| Version v1
Report
Solids filtration of high-temperature feedwater in a PWR secondary circuit: Final report
Description
Pressurized water reactor steam generators and turbines have experienced a variety of corrosion problems as a result of ionic, corrosion product and oxidizing species transport to the steam generators. Installation of high temperature filters on final feedwater, high pressure drains and moisture separator drains to reduce corrosion product ingress to the steam generators of a 1160 MWe design basis plant are specified and evaluated. Cost estimates for installing electromagnetic filters, and added operating and maintenance costs are given. 18 refs., 12 figs., 9 tabs
Availability note (English)
Research Reports Center, Box 50490, Palo Alto, CA 94303.Additional details
Publishing Information
- Imprint Pagination
- 50 p.
- Report number
- EPRI-NP--6097
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 20030278
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Non-conventional Literature
- Descriptors DEI
- CORROSION; ELECTROMAGNETIC FILTERS; FEEDWATER; FILTRATION; PWR TYPE REACTORS; SECONDARY COOLANT CIRCUITS; SLURRIES; STEAM GENERATORS; WATER CHEMISTRY
- Descriptors DEC
- BOILERS; CHEMICAL REACTIONS; COOLING SYSTEMS; DISPERSIONS; ENRICHED URANIUM REACTORS; FILTERS; HYDROGEN COMPOUNDS; MIXTURES; OXYGEN COMPOUNDS; POLAR SOLVENTS; POWER REACTORS; REACTOR COMPONENTS; REACTOR COOLING SYSTEMS; REACTORS; SEPARATION PROCESSES; SOLVENTS; SUSPENSIONS; THERMAL REACTORS; VAPOR GENERATORS; WATER; WATER COOLED REACTORS; WATER MODERATED REACTORS; WATER TREATMENT