Published February 1999 | Version v1
Report Open

Additional reactor protection system of RBMK-1500

Description

Analysis of anticipated transients without scram of RBMK-1500 reactor showed that additional reactor protection system is required. Data of accident analysis in the case of loose of external electric power and loose of vacuum in condensers of turbines are provided

Files

30025920.pdf

Files (149.4 kB)

Name Size Download all
md5:eb7d1435dd39855758b2f69c22bb9d4e
149.4 kB Preview Download
Part of:
Ignalina Safety Analysis Group's report for the year 1998

Additional details

Additional titles

Original title (Lithuanian)
RBMK-1500 reaktoriaus papildoma avarinio stabdymo sistema

Publishing Information

Imprint Title
Ignalina Safety Analysis Group's report for the year 1998
Imprint Pagination
69 p.
Journal Page Range
p. 42-45
Report number
ISAG--98

Optional Information

Notes
1 figs., 1 tabs. Imprint:31 refs., 40 figs., 4 tabs.;Ignalinos atomines elektrines mokslines saugos analizes grupes 1998 metu veiklos ataskaita