Published 1993
| Version v1
Report
Open
Isotope separation of 22Na and 24Na with using light induced drift effect
Description
The LIDIS (Light Drift Isotope Separation) separator without a gas flow is discussed. It is shown, that atomization degree of the separated isotopes limited real separation coefficient. The better buffer gas purification allowed to increase the experimental separation factor of 22Na and 24Na isotopes up to 25. The new experimental set up allow to increase the separation efficiency up to 50%. 12 refs.; 5 figs
Availability note (English)
MF available from INIS under the Report Number.Files
25000732.pdf
Files
(222.9 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:08a9fac0eb0ce86e3953214f85e87c50
|
222.9 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 14 p.
- Report number
- JINR-E--13-93-17
INIS
- Country of Publication
- Russian Federation
- Country of Input or Organization
- Russian Federation
- INIS RN
- 25000732
- Subject category
- S07: ISOTOPES AND RADIATION SOURCES;
- Descriptors DEI
- EFFICIENCY; LASER ISOTOPE SEPARATION; PURIFICATION; SODIUM 22; SODIUM 24; WAVELENGTHS
- Descriptors DEC
- BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; BETA-PLUS DECAY RADIOISOTOPES; HOURS LIVING RADIOISOTOPES; ISOMERIC TRANSITION ISOTOPES; ISOTOPE SEPARATION; ISOTOPES; LIGHT NUCLEI; MILLISEC LIVING RADIOISOTOPES; NANOSEC LIVING RADIOISOTOPES; NUCLEI; ODD-ODD NUCLEI; RADIOISOTOPES; SEPARATION PROCESSES; SODIUM ISOTOPES; YEARS LIVING RADIOISOTOPES