Spectromicroscopic film dosimetry for high-energy microbeam from synchrotron radiation

  • 1. Japan Synchrotron Radiation Research Institute, Kouto 1-1-1, Sayo, Hyogo 679-5198 (Japan)
  • 2. Research Reactor Institute, Kyoto University, Kumatori, Sennan, Osaka 590-0494 (Japan)
  • 3. Institute of Development, Aging and Cancer, Tohoku University, Seiryo, Aoba, Sendai, Miyagi 980-8575 (Japan)
  • 4. Kobe University, Graduate School of Medicine, Kusunoki, Chuo, Kobe, Hyogo 650-0017 (Japan)

Description

A microscope with band-pass filters was used to measure the optical-density distribution of GafChromic films irradiated with multi-slit microbeam X-rays. The planar width was 25 μm, and the center-to-center distance was 200 μm. The peak and valley dose rates in air were found to be 120 and 0.7 Gy/s, respectively. In a polymethylmethacrylate phantom, the peak-to-valley dose ratio decreased to 80 at a 1-mm depth. Doses calculated with the PENELOPE code agreed with those around the peak but became smaller in the valley

Availability note (English)

Available from http://dx.doi.org/10.1016/j.apradiso.2008.08.002

Additional details

Identifiers

DOI
10.1016/j.apradiso.2008.08.002;
PII
S0969-8043(08)00406-5;

Publishing Information

Journal Title
Applied Radiation and Isotopes
Journal Volume
67
Journal Issue
1
Journal Page Range
p. 155-159
ISSN
0969-8043
CODEN
ARISEF

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
40043373
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY;
Descriptors DEI
DISTRIBUTION; DOSE RATES; FILM DOSIMETRY; FILMS; FILTERS; IRRADIATION; MICROSCOPES; RADIATION DOSES; SYNCHROTRON RADIATION; X RADIATION
Descriptors DEC
BREMSSTRAHLUNG; DOSES; DOSIMETRY; ELECTROMAGNETIC RADIATION; IONIZING RADIATIONS; RADIATIONS