Published May 21, 2011
| Version v1
Journal article
An innovative approach to compact calorimetry in space, NEUCAL
Creators
- 1. INFN Sezione di Firenze, via Sansone, 1-I-50019 Sesto F. no (Italy)
- 2. University of Florence, via Sansone, 1-I-50019 Sesto F. no (Italy)
Description
Neutron emission during the development of hadronic showers can be used to discriminate between electromagnetic and hadronic interacting particles impinging a calorimeter. A neutron detector based on a high efficiency 'active moderator' is presented and its performance is evaluated with the aid of Monte Carlo simulation.
Availability note (English)
Available from http://dx.doi.org/10.1016/j.nima.2009.10.089Additional details
Identifiers
- DOI
- 10.1016/j.nima.2009.10.089;
- PII
- S0168-9002(09)02017-8;
Publishing Information
- Journal Title
- Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
- Journal Volume
- 617
- Journal Issue
- 1-3
- Journal Page Range
- p. 464-466
- ISSN
- 0168-9002
- CODEN
- NIMAER
Conference
- Title
- 11. Pisa meeting on advanced detectors
- Dates
- 24-30 May 2009
- Place
- La Biodola, Elba (Italy)
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 42009449
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- CALORIMETERS; CALORIMETRY; COMPUTERIZED SIMULATION; EFFICIENCY; HADRONS; MODERATORS; MONTE CARLO METHOD; NEUTRON DETECTORS; NEUTRON EMISSION; PERFORMANCE; SHOWERS; SPACE
- Descriptors DEC
- CALCULATION METHODS; ELEMENTARY PARTICLES; EMISSION; MEASURING INSTRUMENTS; RADIATION DETECTORS; SIMULATION
Optional Information
- Copyright
- Copyright (c) 2009 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.