Published May 2012
| Version v1
Miscellaneous
Data Management Tool Design for Eddy Current Testing of Steam Generator Tube in NPP
- 1. Korea Hydro and Nuclear Power Co., Daejeon (Korea, Republic of)
Description
Eddy current testing (ECT) is mainly applied for the in-service inspection(ISI) of steam generator tube in Nuclear Power Plants. Presently, there is no domestic ECT system for the steam generator tubes. The maintenance and repair of the imported system cannot be achieved effectively. In order to resolve such problem, new ECT system has now been being developed in KHNP Central Research Institute. In this paper, the composition and functions of the steam generator ECT Data Management are explained
Additional details
Publishing Information
- Publisher
- KNS
- Imprint Place
- Daejeon (Korea, Republic of)
- Imprint Title
- Proceedings of the KNS spring meeting
- Imprint Pagination
- [1 CD-ROM]
- Journal Page Range
- [2 p.]
Conference
- Title
- 2012 spring meeting of the KNS
- Dates
- 16-18 May 2012
- Place
- Jeju (Korea, Republic of)
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 43073780
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- DATA; DESIGN; EDDY CURRENT TESTING; IN-SERVICE INSPECTION; MAINTENANCE; NUCLEAR POWER PLANTS; REPAIR; STEAM GENERATORS; TUBES
- Descriptors DEC
- BOILERS; ELECTROMAGNETIC TESTING; INFORMATION; INSPECTION; MATERIALS TESTING; NONDESTRUCTIVE TESTING; NUCLEAR FACILITIES; POWER PLANTS; TESTING; THERMAL POWER PLANTS; VAPOR GENERATORS
Optional Information
- Notes
- 3 refs, 3 figs