Published October 1995
| Version v1
Journal article
Calibration factor for LR-115 type II track detectors for environmental radon measurements
Creators
- 1. Aligarh Muslim Univ. (India). Z.H. Coll. of Engineering and Technology
- 2. Bhabha Atomic Research Centre, Bombay (India). Environmental Assessment Div.
Description
This paper presents the experimental calibration of LR-115 type II plastic track detectors for monitoring environmental radon. The detectors were calibrated using a standard radon chamber and simulating the environmental conditions as normally found in dwellings. The value of the calibration factor was found to be 625 tracks cm-2 d-1 per WL in the BARE mode and 0.116 tracks cm-2 d-1 per Bq m-3 for cup with membrane mode. Results of measurements of radon and its daughters in Bijnor (India) are also presented. (author)
Additional details
Publishing Information
- Journal Title
- Nuclear Geophysics
- Journal Volume
- 9
- Journal Issue
- 5
- Journal Page Range
- p. 487-495.
- ISSN
- 0969-8086
- CODEN
- NUGEEP
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- United Kingdom
- INIS RN
- 27010567
- Subject category
- S54: ENVIRONMENTAL SCIENCES;
- Descriptors DEI
- CALIBRATION; DIELECTRIC TRACK DETECTORS; HOUSES; PLASTICS; RADIATION MONITORING; RADON
- Descriptors DEC
- BUILDINGS; ELEMENTS; MEASURING INSTRUMENTS; MONITORING; NONMETALS; ORGANIC COMPOUNDS; ORGANIC POLYMERS; PETROLEUM PRODUCTS; POLYMERS; RADIATION DETECTORS; RARE GASES; RESIDENTIAL BUILDINGS