Signal processing in the calorimeter pre-trigger of the CMD-3 detector

  • 1. Budker Institute of Nuclear Physics, 11 Lavrentieva ave., Novosibirsk 630090 (Russian Federation)

Description

The CMD-3 detector includes a magnetic spectrometer and an electromagnetic calorimeter. The calorimeters' signals are used for energy deposition measurement and for triggering. For triggering, the calorimeters' signals are transformed into special short-shaped analog signals. These signals are then digitally processed with special algorithm, which allows one to obtain a set of logic signals necessary for event selection and a time-tag signal for time alignment of time measurements. In this paper, the main features of the developed signal processing algorithm are described.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.nima.2008.08.037

Additional details

Identifiers

DOI
10.1016/j.nima.2008.08.037;
PII
S0168-9002(08)01259-X;

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
598
Journal Issue
1
Journal Page Range
p. 345-348
ISSN
0168-9002
CODEN
NIMAER

Conference

Title
10. international conference on instrumentation for colliding beam physics
Dates
28 Feb - 5 Mar 2008
Place
Novosibirsk (Russian Federation)

INIS

Country of Publication
Netherlands
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
41009569
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ALGORITHMS; ALIGNMENT; DATA ACQUISITION; MAGNETIC SPECTROMETERS; PROCESSING; SIGNALS; TIME MEASUREMENT
Descriptors DEC
MATHEMATICAL LOGIC; MEASURING INSTRUMENTS; SPECTROMETERS