Renal denervation for refractory hypertension. Technical aspects, complications and radiation exposure
Creators
- 1. Charite Universitatesmedizin, Berlin (Germany). Radiologie
- 2. Charite Universitatesmedizin, Berlin (Germany). Nephrologie
- 3. DRK Klinikum Berlin Mitte, Berlin (Germany). Radiologie
Description
Purpose: To analyze procedural details, complications and radiation exposure in renal denervation (RDN) using the Medtronic Symplicity registered device in the treatment of refractory hypertension. Materials and Methods: Fifty three consecutive patients underwent RDN. The number of ablations per artery, peri-procedural complications, procedure time (PT), fluoroscopy time (FT), dose-area product (DAP) and procedure-related complications were documented. Additionally, the radiation dose was compared between obese (body mass index ≥ 30 kg/m2) and non-obese patients. Results: Bilateral RDN was performed in 50/53 (94 %) cases and with a minimum of 4 ablations per artery in 33/50 (66 %), the mean count being 5.4 (range R: 2 - 13) on the right and 4.3 (R: 1 - 10) on the left. The FT and DAP decreased significantly over the first 12 procedures, reaching a steady state with a median FT of 11.2 min (R: 7.5 - 27) and a median DAP of 4796 cGy x cm2 (R: 1076 - 21 371), resulting in an effective dose of 15.7 mSv. The median PT was 57 min (R: 40 - 70). Obese patients had a 3.3-fold higher radiation dose (p < 0.001). We observed one severe spasm and one imminent respiratory depression, both resolved without sequelae. Conclusion: For an experienced interventionalist, RDN has a short learning curve with a low risk profile. The radiation dose does not exceed that of other renal artery interventions, but is explicitly higher in obese patients, who account for a large portion of patients with refractory hypertension. (orig.)
Additional details
Publishing Information
- Journal Title
- RoeFo - Fortschritte auf dem Gebiete der Roentgenstrahlen und der Bildgebenden Verfahren
- Journal Volume
- 185
- Journal Issue
- 6
- Journal Page Range
- p. 550-557
- ISSN
- 1438-9029
- CODEN
- RFGNDO
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 44080420
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ABLATION; ANATOMY; ANESTHESIA; ARTERIES; BIOMEDICAL RADIOGRAPHY; FLUOROSCOPY; HYPERTENSION; KIDNEYS; MALFORMATIONS; RADIATION DOSES; RADIOLOGY; SURGERY; X-RAY RADIOGRAPHY
- Descriptors DEC
- BIOLOGY; BIOMEDICAL RADIOGRAPHY; BLOOD VESSELS; BODY; CARDIOVASCULAR DISEASES; CARDIOVASCULAR SYSTEM; DIAGNOSTIC TECHNIQUES; DISEASES; DOSES; INDUSTRIAL RADIOGRAPHY; MATERIALS TESTING; MEDICINE; NONDESTRUCTIVE TESTING; NUCLEAR MEDICINE; ORGANS; PATHOLOGICAL CHANGES; RADIOLOGY; SYMPTOMS; TESTING; VASCULAR DISEASES