Published March 12, 2008 | Version v1
Journal article

Neutron Compton scattering anomaly verified with Rh-resonance foil

  • 1. Department of Physics, Uppsala University, PO Box 530, SE-75121 Uppsala (Sweden)
  • 2. Institute of Chemistry, Stranski Laboratory, Technische Universitaet Berlin, D-10623 Berlin (Germany)

Description

Compton scattering experiments with neutrons usually employ Au- or U-foils for energy selection of the scattered neutrons. A series of experiments on various H-containing materials have shown a large deficit in the scattering intensity of protons using Au-foils and it has been claimed that the anomalies arise from a faulty analysis of the data by neglecting effects of the tails of the Au-resonance lines. In the present experiments a Rh-103 resonance foil is used. It has considerably different resonance characteristics, but the H/metal ratio derived shows nearly the same anomalous value as with Au-foils. The present result therefore supports the existence of the mentioned anomalies

Availability note (English)

Available from http://dx.doi.org/10.1088/0953-8984/20/10/104248

Additional details

Identifiers

DOI
10.1088/0953-8984/20/10/104248;
PII
S0953-8984(08)55006-5;

Publishing Information

Journal Title
Journal of Physics. Condensed Matter
Journal Volume
20
Journal Issue
10
Journal Page Range
[3 p.]
ISSN
0953-8984
CODEN
JCOMEL

Conference

Title
4. European conference on neutron scattering
Dates
25-29 Jun 2007
Place
Lund (Sweden)