Published December 2021 | Version v1
Journal article

Validation of photoneutron energy distributions in shielding calculation of the medical linac room

  • 1. Shimizu Corporation, Institute of Technology, Tokyo (Japan)

Description

It is necessary to consider the effect of photoneutrons produced by photonuclear reactions in the shielding calculation of a medical linac room with incident electron energies greater than 10 MeV. For photonuclear reaction files, the validation of photoneutron energy distributions has not been reported. We compared the evaluated data of photoneutron energy distributions in LA150 and JENDL/PD-2016.1 with the experimental data for 11 nuclides taken from the EXFOR database. For dominant shielding materials of linac, we validated the tendency of energy distributions by comparing the experimental data of neighborhood nuclides. Consequently, we found problems in the evaluations of the photoneutron energy distributions of the photonuclear reaction files. (author)

Availability note (English)

Available from DOI: https://doi.org/10.3327/taesj.J20.016

Additional details

Additional titles

Original title (Japanese)
医療用リニアック室の遮蔽計算における光中性子のエネルギー分布の妥当性

Identifiers

Publishing Information

Journal Title
Nippon Genshiryoku Gakkai Wabun Ronbunshi (Online)
Journal Volume
20
Journal Issue
4
Series
雑誌名:日本原子力学会和文論文誌
Journal Page Range
p. 143-158
ISSN
2186-2931

Optional Information

Notes
19 refs., 32 figs., 1 tab.