Published May 1, 2011 | Version v1
Journal article

Managing Systematic Errors in a Polarimeter for the Storage Ring EDM Experiment

  • 1. Indiana University, Bloomington, IN, 47408 (United States)

Description

The EDDA plastic scintillator detector system at the Cooler Synchrotron (COSY) has been used to demonstrate that it is possible using a thick target at the edge of the circulating beam to meet the requirements for a polarimeter to be used in the search for an electric dipole moment on the proton or deuteron. Emphasizing elastic and low Q-value reactions leads to large analyzing powers and, along with thick targets, to efficiencies near 1%. Using only information obtained comparing count rates for oppositely vector-polarized beam states and a calibration of the sensitivity of the polarimeter to rate and geometric changes, the contribution of systematic errors can be suppressed below the level of one part per million.

Availability note (English)

Available from http://dx.doi.org/10.1088/1742-6596/295/1/012140