Characterization of a medical X-ray machine for testing the response of electronic dosimeters in pulsed radiation fields
- 1. Postgraduation Course of Science and Technology of Radiations, Minerals and Materials, CDTN/CNEN, Belo Horizonte (Brazil)
- 2. Development Center of Nuclear Technology, CDTN/CNEN, Belo Horizonte (Brazil)
Description
Electronic personal dosimeters (EPD) based on solid state detectors have been used for personnel monitoring for radiation protection purpose; their use has been extended to practices with pulsed radiation beams although their performance is not well known. Deficiencies in the EPD response in pulsed radiation fields have been reported; they were not detected before since type tests and calibrations of EPDs were established in terms of continuous X and gamma reference radiations. An ISO working group was formed to elaborate a standard for test conditions and performance requirements of EPDs in pulsed beams; the PTB/Germany implemented a special X-ray facility for generating the reference pulsed radiation beams. In this work, an 800 Plus VMI medical X-ray machine of the Dosimeter Calibration Laboratory of CDTN/CNEN was characterized to verify its feasibility to perform EPD tests. Characterization of the x-ray beam was done in terms of practical peak voltage, half-value layer, mean energy and air kerma rate. Reference dosimeters used for air kerma measurements were verified as far their metrological coherence and a procedure for testing EDPs was established. - highlights: • Electronic personal dosimeters (EPD) have been used for personnel monitoring. • EPD use has been extended to pulsed radiation beams. • Deficiencies in the EPD response in pulsed beams have been reported. • The feasibility of using a medical X-ray machine to perform EPD tests was studied. • Reference dosimeters were verified and EPD testing procedure was established
Availability note (English)
Available from http://dx.doi.org/10.1016/j.radphyschem.2013.10.019Additional details
Identifiers
- DOI
- 10.1016/j.radphyschem.2013.10.019;
- PII
- S0969-806X(13)00578-1;
Publishing Information
- Journal Title
- Radiation Physics and Chemistry (1993)
- Journal Volume
- 104
- Journal Page Range
- p. 321-323
- ISSN
- 0969-806X
- CODEN
- RPCHDM
Conference
- Title
- 1. international conference on dosimetry and its applications
- Dates
- 23-28 Jun 2013
- Place
- Prague (Czech Republic)
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 46124303
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- CALIBRATION; CNEN; DOSEMETERS; FEDERAL REPUBLIC OF GERMANY; GAMMA DOSIMETRY; KERMA; LAYERS; PERFORMANCE; PERSONNEL MONITORING; PULSED IRRADIATION; RADIATION PROTECTION; STANDARDS; TESTING; X RADIATION; X-RAY DOSIMETRY
- Descriptors DEC
- DEVELOPED COUNTRIES; DOSIMETRY; ELECTROMAGNETIC RADIATION; EUROPE; IONIZING RADIATIONS; IRRADIATION; ITALIAN ENEA; ITALIAN ORGANIZATIONS; MEASURING INSTRUMENTS; MONITORING; NATIONAL ORGANIZATIONS; RADIATION MONITORING; RADIATIONS; WESTERN EUROPE
Optional Information
- Copyright
- Copyright (c) 2013 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.