Characterization of a medical X-ray machine for testing the response of electronic dosimeters in pulsed radiation fields

  • 1. Postgraduation Course of Science and Technology of Radiations, Minerals and Materials, CDTN/CNEN, Belo Horizonte (Brazil)
  • 2. Development Center of Nuclear Technology, CDTN/CNEN, Belo Horizonte (Brazil)

Description

Electronic personal dosimeters (EPD) based on solid state detectors have been used for personnel monitoring for radiation protection purpose; their use has been extended to practices with pulsed radiation beams although their performance is not well known. Deficiencies in the EPD response in pulsed radiation fields have been reported; they were not detected before since type tests and calibrations of EPDs were established in terms of continuous X and gamma reference radiations. An ISO working group was formed to elaborate a standard for test conditions and performance requirements of EPDs in pulsed beams; the PTB/Germany implemented a special X-ray facility for generating the reference pulsed radiation beams. In this work, an 800 Plus VMI medical X-ray machine of the Dosimeter Calibration Laboratory of CDTN/CNEN was characterized to verify its feasibility to perform EPD tests. Characterization of the x-ray beam was done in terms of practical peak voltage, half-value layer, mean energy and air kerma rate. Reference dosimeters used for air kerma measurements were verified as far their metrological coherence and a procedure for testing EDPs was established. - highlights: • Electronic personal dosimeters (EPD) have been used for personnel monitoring. • EPD use has been extended to pulsed radiation beams. • Deficiencies in the EPD response in pulsed beams have been reported. • The feasibility of using a medical X-ray machine to perform EPD tests was studied. • Reference dosimeters were verified and EPD testing procedure was established

Availability note (English)

Available from http://dx.doi.org/10.1016/j.radphyschem.2013.10.019

Additional details

Identifiers

DOI
10.1016/j.radphyschem.2013.10.019;
PII
S0969-806X(13)00578-1;

Publishing Information

Journal Title
Radiation Physics and Chemistry (1993)
Journal Volume
104
Journal Page Range
p. 321-323
ISSN
0969-806X
CODEN
RPCHDM

Conference

Title
1. international conference on dosimetry and its applications
Dates
23-28 Jun 2013
Place
Prague (Czech Republic)

Optional Information

Copyright
Copyright (c) 2013 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.