Published October 1, 2006 | Version v1
Journal article

Consistency in seroma contouring for partial breast radiotherapy: Impact of guidelines

  • 1. Radiation Therapy Program, British Columbia (BC) Cancer Agency, Vancouver Island Centre, Victoria and Vancouver, BC (Canada)
  • 2. Radiation Therapy Program, British Columbia (BC) Cancer Agency, Vancouver Island Centre, Victoria and Vancouver, BC (Canada) and University of British Columbia, Victoria and Vancouver, BC (Canada)
  • 3. University of British Columbia, Victoria and Vancouver, BC (Canada)
  • 4. Vancouver Centre, Victoria and Vancouver, BC (Canada)

Description

Purpose: Inconsistencies in contouring target structures can undermine the precision of conformal radiation therapy (RT) planning and compromise the validity of clinical trial results. This study evaluated the impact of guidelines on consistency in target volume contouring for partial breast RT planning. Methods and Materials: Guidelines for target volume definition for partial breast radiation therapy (PBRT) planning were developed by members of the steering committee for a pilot trial of PBRT using conformal external beam planning. In phase 1, delineation of the breast seroma in 5 early-stage breast cancer patients was independently performed by a 'trained' cohort of four radiation oncologists who were provided with these guidelines and an 'untrained' cohort of four radiation oncologists who contoured without guidelines. Using automated planning software, the seroma target volume (STV) was expanded into a clinical target volume (CTV) and planning target volume (PTV) for each oncologist. Means and standard deviations were calculated, and two-tailed t tests were used to assess differences between the 'trained' and 'untrained' cohorts. In phase 2, all eight radiation oncologists were provided with the same contouring guidelines, and were asked to delineate the seroma in five new cases. Data were again analyzed to evaluate consistency between the two cohorts. Results: The 'untrained' cohort contoured larger seroma volumes and had larger CTVs and PTVs compared with the 'trained' cohort in three of five cases. When seroma contouring was performed after review of contouring guidelines, the differences in the STVs, CTVs, and PTVs were no longer statistically significant. Conclusion: Guidelines can improve consistency among radiation oncologists performing target volume delineation for PBRT planning

Additional details

Identifiers

DOI
10.1016/j.ijrobp.2006.05.066;
PII
S0360-3016(06)00967-9;

Publishing Information

Journal Title
International Journal of Radiation Oncology, Biology and Physics
Journal Volume
66
Journal Issue
2
Journal Page Range
p. 372-376
ISSN
0360-3016
CODEN
IOBPD3

INIS

Country of Publication
United States
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
38020571
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
ACCURACY; CLINICAL TRIALS; COMPUTER CODES; MAMMARY GLANDS; MEDICAL PERSONNEL; PATIENTS; PLANNING; RADIOTHERAPY; RECOMMENDATIONS; REVIEWS
Descriptors DEC
BODY; DOCUMENT TYPES; GLANDS; MEDICINE; NUCLEAR MEDICINE; ORGANS; PERSONNEL; RADIOLOGY; TESTING; THERAPY

Optional Information

Copyright
Copyright (c) 2006 Elsevier Science B.V., Amsterdam, Netherlands, All rights reserved.