VIP polymer gel dosimeter was used for Carbon ion beam dosimetry using a 150 MeV/n beam with 10 Gy plateau dose and a SOBP irradiation scheme with 5 Gy Bragg peak dose. The results show a decrease by 8 mm in the expected from Monte Carlo simulation range in water, suggesting that the dosimeter is non water equivalent. However VIP shows efficiency close to 1 in the plateau region and significantly reduced efficiency in the peak. On the other hand the SOBP results yield an efficiency close to 1 in the SOBP implying that the dose response of the VIP dosimeter may not be solely related to LET.