Published December 1, 2013 | Version v1
Journal article

Dose Uncertainties in IMPT for Oropharyngeal Cancer in the Presence of Anatomical, Range, and Setup Errors

  • 1. Erasmus MC Daniel den Hoed Cancer Center, Rotterdam (Netherlands)
  • 2. Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts (United States)

Description

Purpose: Setup, range, and anatomical uncertainties influence the dose delivered with intensity modulated proton therapy (IMPT), but clinical quantification of these errors for oropharyngeal cancer is lacking. We quantified these factors and investigated treatment fidelity, that is, robustness, as influenced by adaptive planning and by applying more beam directions. Methods and Materials: We used an in-house treatment planning system with multicriteria optimization of pencil beam energies, directions, and weights to create treatment plans for 3-, 5-, and 7-beam directions for 10 oropharyngeal cancer patients. The dose prescription was a simultaneously integrated boost scheme, prescribing 66 Gy to primary tumor and positive neck levels (clinical target volume-66 Gy; CTV-66 Gy) and 54 Gy to elective neck levels (CTV-54 Gy). Doses were recalculated in 3700 simulations of setup, range, and anatomical uncertainties. Repeat computed tomography (CT) scans were used to evaluate an adaptive planning strategy using nonrigid registration for dose accumulation. Results: For the recalculated 3-beam plans including all treatment uncertainty sources, only 69% (CTV-66 Gy) and 88% (CTV-54 Gy) of the simulations had a dose received by 98% of the target volume (D98%) >95% of the prescription dose. Doses to organs at risk (OARs) showed considerable spread around planned values. Causes for major deviations were mixed. Adaptive planning based on repeat imaging positively affected dose delivery accuracy: in the presence of the other errors, percentages of treatments with D98% >95% increased to 96% (CTV-66 Gy) and 100% (CTV-54 Gy). Plans with more beam directions were not more robust. Conclusions: For oropharyngeal cancer patients, treatment uncertainties can result in significant differences between planned and delivered IMPT doses. Given the mixed causes for major deviations, we advise repeat diagnostic CT scans during treatment, recalculation of the dose, and if required, adaptive planning to improve adequate IMPT dose delivery

Availability note (English)

Available from http://dx.doi.org/10.1016/j.ijrobp.2013.09.014

Additional details

Identifiers

DOI
10.1016/j.ijrobp.2013.09.014;
PII
S0360-3016(13)03101-5;

Publishing Information

Journal Title
International Journal of Radiation Oncology, Biology and Physics
Journal Volume
87
Journal Issue
5
Journal Page Range
p. 888-896
ISSN
0360-3016
CODEN
IOBPD3

INIS

Country of Publication
United States
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
45099621
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
ACCURACY; CAT SCANNING; CRITICAL ORGANS; ION BEAMS; NECK; NEOPLASMS; PLANNING; PROTONS; RADIATION DOSES; RADIOTHERAPY
Descriptors DEC
BARYONS; BEAMS; BODY; COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; DISEASES; DOSES; ELEMENTARY PARTICLES; FERMIONS; HADRONS; MEDICINE; NUCLEAR MEDICINE; NUCLEONS; ORGANS; RADIOLOGY; THERAPY; TOMOGRAPHY

Optional Information

Copyright
Copyright (c) 2013 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.