Published January 2009 | Version v1
Journal article

Evaluation of a New Balloon Catheter for Difficult Calcified Lesions in Infrainguinal Arterial Disease: Outcome of a Multicenter Registry

  • 1. Radboud University Nijmegen Medical Centre, Department of Radiology (Netherlands)
  • 2. Beaumont Hospital, Department of Radiology (Ireland)
  • 3. Amsterdam Medical Centre, Amsterdam, Department of Radiology (Netherlands)
  • 4. Leyenburg Hospital, Department of Radiology (Netherlands)

Description

The purpose of this study was to assess the technical performance and immediate procedure outcome of a new balloon catheter in the treatment of calcified lesions in infrainguinal arterial disease. Seventy-five patients with infrainguinal arterial disease were prospectively entered into the registry. The catheter (ReeKross Clearstream, Ireland) is a 5- to 6-Fr balloon catheter with a rigid shaft intended for enhanced pushability. Only technical procedural outcome was recorded. Treated calcified lesions (range: 5-30 cm), assessed angiographically, were located in the superficial femoral, popliteal, and crural arteries. In 67 patients the lesion was an occlusion. Guidewire passage occurred subintimally in 68 patients. In 24 patients a standard balloon catheter was chosen as first treatment catheter: 5 failed to cross the lesion, 8 balloons ruptured, and in 11 patients there was an inadequate dilatation result. In only one of the five patients did subsequent use of the ReeKross catheter also fail in lesion crossing. The ReeKross was successful as secondary catheter in the other 23 cases. In 50 patients the ReeKross was used as primary catheter. In total the ReeKross crossed the lesions in 74 patients. After passage and dilatation with this catheter in 73 patients (1 failed true-lumen reentry), 19 had >30% residual lesions, of which 11 were not treated and 8 were successfully stented. No ReeKross balloons ruptured. We conclude that in the treatment of difficult calcified lesions in arterial stenotic or occlusive disease, the choice of a high-pushability angioplasty catheter, with more calcification-resistant balloon characteristics, like the ReeKross, warrants consideration.

Additional details

Identifiers

Publishing Information

Journal Title
Cardiovascular and Interventional Radiology
Journal Volume
32
Journal Issue
1
Journal Page Range
p. 132-135
ISSN
0174-1551
CODEN
CAIRDG

Conference

Title
Annual meeting of the Cardiovascular and Interventional Radiology Society of Europe
Acronym
BSIR 2008
Dates
5-7 Nov 2008
Place
Manchester (United Kingdom)

INIS

Country of Publication
United States
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
42045211
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ARTERIES; DISEASES; EVALUATION
Descriptors DEC
BLOOD VESSELS; BODY; CARDIOVASCULAR SYSTEM; ORGANS

Optional Information

Copyright
Copyright (c) 2008 The Author(s)