Published 2004 | Version v1
Miscellaneous

The analysis of circumference through-wall cracked pipe considering weld characteristic

  • 1. Korea Univ., Seoul (Korea, Republic of)
  • 2. Sungkyunkwan Univ., Suwon (Korea, Republic of)
  • 3. Korea Electric Power Research Institute, Taejon (Korea, Republic of)

Description

Defective components of interest include not only homogeneous components, but also components with weldments where tensile properties vary across the weldment. Noting that the region near the weldment is the most vulnerable place for crack initiation and subsequent growth, defect assessment methods for homogeneous structure. Moreover, weldment width and crack location also affects the deformation and fracture behavior of the welded joints. These weld characteristics can evaluate using plastic limit load. So in this paper, evaluate plastic limit load both full circumference part-throughwall cracked pipes and circumference through-wall cracked pipes considering weld characteristics. And using evaluate results, proposed J-integral and Crack Opening Displacement(COD) estimate method based on reference stress method

Part of:
Proceedings of the KSME 2004 fall annual meeting

Additional details

Publishing Information

Publisher
KSME
Imprint Place
Seoul (Korea, Republic of)
Imprint Title
Proceedings of the KSME 2004 fall annual meeting
Imprint Pagination
[1 CD-ROM]
Journal Page Range
[6 p.]

Conference

Title
KSME 2004 fall annual meeting
Dates
3-5 Nov 2004
Place
Taejon (Korea, Republic of)

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
36017337
Subject category
S36: MATERIALS SCIENCE;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
CRACKS; DEFECTS; DEFORMATION; FINITE ELEMENT METHOD; FRACTURES; GROWTH; NUCLEAR POWER PLANTS; PIPES; TENSILE PROPERTIES; WELDING
Descriptors DEC
CALCULATION METHODS; FABRICATION; FAILURES; JOINING; MATHEMATICAL SOLUTIONS; MECHANICAL PROPERTIES; NUCLEAR FACILITIES; NUMERICAL SOLUTION; POWER PLANTS; THERMAL POWER PLANTS; TUBES

Optional Information

Notes
9 refs, 8 figs, 4 tabs