Published 1999 | Version v1
Journal article

WEC program for calculation of system of accelerating voltage pulses formation on lines with distributed parameters

  • 1. VNIIEF, Sarov (Russian Federation)

Description

There were conducted calculations of one of operation modes of STRAUS-2 accelerator.Calculation diode current pulses were compared to current pulses measured experimentally. From the comparison it is clear that the difference of time-amplitude parameters of calculation pulse from those of experimental current pulse do not exceed 10%, what is within the accuracy of measurements

Additional details

Publishing Information

Journal Title
Voprosy Atomnoj Nauki i Tekhniki. Yaderno-Fizicheskie Issledovaniya
Journal Issue
no.4/35/
Journal Page Range
p. 74-76
ISSN
1562-6016