A study on the optimization of decision technique about RCS leakage inside containment vessel

  • 1. Chosun University, Gwangju (Korea, Republic of)

Description

Due to the increase in the number of operating nuclear plants, the experience of Reactor Coolant System leakage has been continuously increased. Since commercial operations began with Kori Unit 1 in April 1978, the number of unplanned reactor trips due to RCS leakage inside containment vessel is fifteen as of the end of 2001. Reactor operator's quick decision and action on RCS leakage are very important in order to minimize unplanned shutdowns and to prevent radiation contamination and accident extension due to RCS leakage. Therefore in this study, optimization techniques are suggested to decide RCS leakage inside containment vessel through the results of the analysis of simulation and operation experience examples

Part of:
Proceedings of the KNS spring meeting

Additional details

Publishing Information

Publisher
KNS
Imprint Place
Taejon (Korea, Republic of)
Imprint Title
Proceedings of the KNS spring meeting
Imprint Pagination
[CD-ROM]
Journal Page Range
[15 p.]

Conference

Title
2003 spring meeting of the KNS
Dates
29-30 May 2003
Place
Gyeongju (Korea, Republic of)

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
35063837
Subject category
S22: GENERAL STUDIES OF NUCLEAR REACTORS;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
COMPUTERIZED SIMULATION; CONTAINMENT; LEAKS; REACTOR COOLING SYSTEMS; REACTOR OPERATION
Descriptors DEC
COOLING SYSTEMS; ENERGY SYSTEMS; OPERATION; REACTOR COMPONENTS; SIMULATION

Optional Information

Notes
22 refs, 9 figs, 7 tabs