Published June 1, 2018
| Version v1
Journal article
Various DC-driven point-to-plain discharges as non-thermal plasma sources and their bactericidal effects
- 1. Department of Physics and Measurement, University of Chemistry and Technology in Prague (Czech Republic)
- 2. Institute of Immunology and Microbiology, First Faculty of Medicine, Charles University and General University Hospital in Prague (Czech Republic)
Description
The appearance of several types of ballast serial impedance-stabilized DC-driven electric corona discharges in the point-to-plane configuration is described. In addition to well-known corona discharges, new ones were observed, namely curved transient spark, interrupted channel and branched transient spark. Their properties are described by volt-ampere characteristics and UV-vis emission spectra. Their bactericidal ability for two bacterial species is also given. (paper)
Availability note (English)
Available from http://dx.doi.org/10.1088/1361-6595/aabdd0Additional details
Identifiers
Publishing Information
- Journal Title
- Plasma Sources Science and Technology
- Journal Volume
- 27
- Journal Issue
- 6
- Journal Page Range
- [9 p.]
- ISSN
- 0963-0252
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 52042121
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Descriptors DEI
- BALLASTS; CORONA DISCHARGES; ELECTRIC CONDUCTIVITY; EMISSION SPECTRA; IMPEDANCE; PLASMA; TRANSIENTS
- Descriptors DEC
- ELECTRIC DISCHARGES; ELECTRICAL PROPERTIES; PHYSICAL PROPERTIES; SPECTRA