Published September 1979 | Version v1
Report

Study of safety relief valve operation under ATWS conditions

Description

In March 1979, the NRC published a report (NUREG/CR-0687) prepared by the Energy Technology Engineering Center (ETEC-TDR-78-19). That report presented a literature survey which updated earlier NRC studies of saturated or subcooled water flow through relief valves, under ATWS conditions. This supplement expands upon that search to include supercritical steam-water flow. No applicable data for the supercritical conditions were found, nor were any newer data on saturated or subcooled conditions uncovered. This supplement also updates a look for facilities currently capable of simultaneously imposing all ATWS conditions upon test relief valves. Results confirmed the negative findings of NUREG/CR-0687

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS.

Additional details

Additional titles

Augmented title (English)
Supercritical flow

Publishing Information

Imprint Pagination
35 p.
Report number
NUREG/CR--0687(Suppl.1)

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
11522093
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY;
Descriptors DEI
ATWS; PERFORMANCE; REACTOR COOLING SYSTEMS; TURBULENT FLOW; VALVES
Descriptors DEC
ACCIDENTS; CONTROL EQUIPMENT; COOLING SYSTEMS; DESIGN BASIS ACCIDENTS; FLOW REGULATORS; FLUID FLOW; REACTOR ACCIDENTS; REACTOR COMPONENTS