Evaluating the pacemaker effect with the pump parameter of gated blood-pool imaging
Creators
- 1. Third Hospital Affiliated, Sun Yat-sen University of Medicine Science, Guangzhou (China)
Description
13 normal controls and 27 patients with ventricular pacemaker had undergone planar gated blood-pool imaging in different conditions. Result shows: (1) Pump parameters can successfully reflect therapeutic effect of pacemaker among them EMP is the most valuable parameter for evaluating the cardiac pumping effect. (2) After implantation of the ventricular pacemaker, the LVEF did not increase, but the CO and EMP was significantly increased. (3) Compared with right ventricular demand pacemaker, the rate-responsive ventricular pacemaker give better hemodynamic benefit at exercise condition. (4) Through restrained cardiac pacemaker the functional change was analyzed on or off pace, and monitoring the cardiac function itself after the pacemaker was implanted
Additional details
Publishing Information
- Journal Title
- Nuclear Techniques
- Journal Volume
- 18
- Journal Issue
- 11
- Journal Page Range
- p. 668-672.
- ISSN
- 0253-3219
- CODEN
- NUTEDL
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 27031494
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Resource subtype / Literary indicator
- Numerical Data
- Descriptors DEI
- BLOOD CIRCULATION; CARDIAC PACEMAKERS; CARDIOVASCULAR DISEASES; EVALUATED DATA; EVALUATION; IMAGES; TECHNETIUM 99
- Descriptors DEC
- BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; DATA; DISEASES; HOURS LIVING RADIOISOTOPES; INFORMATION; INTERMEDIATE MASS NUCLEI; INTERNAL CONVERSION RADIOISOTOPES; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; NUCLEI; NUMERICAL DATA; ODD-EVEN NUCLEI; RADIOISOTOPES; TECHNETIUM ISOTOPES; YEARS LIVING RADIOISOTOPES