Published February 1985 | Version v1
Journal article

Investigation of power distribution nonuniformity effect on readings of out-of-pile ionization chambers

Description

Taking as an example South-Ukrainian WWER-1000 type NPP the problems related to the possibility of obtaining integral characteristics of power distribution by readings of out of-pile ionization chambers (IC) are considered. The regression dependence of IC readings on axial offset (AO)-characteristic of peak- power distribution along the core length is investigated. This dependence proved to be linear. For power evaluation linear combination of IC readings is used. Simultaneously by the readings of two IC located at different core length the evaluation of AO values can be performed

Additional details

Additional titles

Original title (Russian)
Исследование влияния неравномерности энергораспределения на показания внереакторных ионизационных камер

Publishing Information

Journal Title
At. Ehnerg.
Journal Volume
58
Journal Issue
2
Series
At. Ehnerg.
Journal Page Range
91-93
ISSN
0004-7163
CODEN
AENGA

Optional Information

Notes
For English translation see the journal Soviet Journal of Atomic Energy (USA).