There is a newer version of the record available.

Published January 2023 | Version v1
Journal article

A feasibility study of different GSI noise indexes and concentrations of contrast medium in hepatic CT angiography of overweight patients. Image quality, radiation dose, and iodine intake

  • 1. Department of Radiology, Affiliated Hospital of Hebei University, Baoding, Hebei (China)

Description

To conduct a comparative study of image quality, radiation dose, and iodine intake in hepatic computed tomographic angiography (CTA) of overweight patients with different Gemstone Spectral Imaging (GSI) noise indexes combined with different concentrations of contrast medium. Ninety patients with a body mass index of ≥25 kg/m2 were divided into three groups (A, B and C), each with 30 patients. The three groups underwent hepatic CTA with different NI of 7, 11 and 15, respectively, and were injected with different iodine concentrations of 370, 350 and 320 mgI/mL, respectively. Five sets of images at 40-60 keV (interval, 5 keV) were reconstructed in each group. The CT value, image noise, contrast-to-noise ratio (CNR) and subjective score of the hepatic artery and vein, and portal vein in different monochromatic image sets were analyzed to select the optimal energy level in each group. The differences in CT value, image noise, CNR and a subjective score of hepatic artery and vein, portal vein in the optimal monochromatic images among the three groups were compared, the volume CT dose index (CTDIvol) and dose-length product (DLP) were recorded, and the effective dose and iodine intake were calculated. The 40 keV was determined to be the optimal energy level for the monochromatic image sets in each group. No significant group differences were noted in the CT value, image noise, CNR, and subjective image scores of the hepatic artery and vein, and portal vein for the optimal monochromatic images (P>0.05). Compared with group A, the effective dose and iodine intake in group B were reduced by 50.18% and 9.3%, and by 58.12% and 14.23% in group C, respectively. A low-concentration contrast medium combined with a high-noise GSI index in hepatic CTA of overweight patients can reduce the radiation dose and iodine intake while ensuring image quality. (author)

Additional details

Identifiers

Publishing Information

Journal Title
Japanese Journal of Radiology (Online)
Journal Volume
41
Journal Issue
6
Journal Page Range
p. 669-679
ISSN
1867-108X

Optional Information

Notes
25 refs., 5 figs., 4 tabs.