Published June 1989 | Version v1
Journal article

Characterization of several ultraviolet--visible emission lines from a lead hollow-cathode lamp

  • 1. CLS-4, Chemistry and Laser Science Division, Los Alamos National Laboratory, Los Alamos, New Mexico 87545
  • 2. Department of Chemistry, New Mexico State University, Las Cruces, New Mexico 88003 (USA)

Description

The Fourier-transform spectra (0.015-cm/sup -1/ resolution) of the nonresonant 405.8-, 368.4-, and 364.0-nm lines and the resonant 283.3-nm line from a lead hollow-cathode lamp are reported. The splittings for the various isotopic and nuclear hyperfine transitions for all four lines are found to be consistent with previous measurements and assignments. At the recommended lamp operating current of 4 mA, all peak shapes within all four lines studied were satisfactorily fitted with Gaussian functions corresponding to the same Doppler temperature of 750+-30 K, indicating no significant self-absorption of the 283.3-nm resonant line. At a much-elevated lamp current the peaks for the nonresonant lines are increased in intensity and slightly broadened, whereas the peaks for the resonant line have approximately the same intensity as at 4 mA but are no longer Gaussian shaped

Additional details

Publishing Information

Journal Title
Journal of the Optical Society of America, Part B: Optical Physics
Journal Volume
6
Journal Issue
6
Series
J. Opt. Soc. Am., B: Opt. Phys.
Journal Page Range
1097-1102
ISSN
0740-3224
CODEN
JOBPD