Published January 1984 | Version v1
Journal article

Large scale magnet system for tandem mirror gamma 10

  • 1. Toshiba Corporation, Yokohama (Japan)

Description

This paper describes design, fabrication and test results of the magnet system for the tandem mirror GAMMA 10. Detailed analyses careful design and fabrication were performed to achieve sophisticated magnetic field distribution with high precision. Test results have revealed that error field is less than 0.2%

Additional details

Publishing Information

Journal Title
J. Phys. (Paris), Colloq.
Journal Volume
45
Journal Issue
C-1
Series
J. Phys. (Paris), Colloq.
Journal Page Range
189-192
ISSN
0449-1947

Conference

Title
8. International conference on magnet technology.
Dates
5-9 Sep 1983.
Place
Grenoble (France).

INIS

Country of Publication
France
Country of Input or Organization
France
INIS RN
15062770
Subject category
S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
JAERI TANDEM ACCELERATOR; MAGNETS; SPECIFICATIONS; TANDEM MIRRORS; TESTING; THERMONUCLEAR DEVICES
Descriptors DEC
ACCELERATORS; ELECTROSTATIC ACCELERATORS; EQUIPMENT; MAGNETIC MIRRORS; OPEN PLASMA DEVICES; TANDEM ELECTROSTATIC ACCELERAT; VAN DE GRAAFF ACCELERATORS