Published February 23, 1980 | Version v1
Report Restricted

Photomultiplier characteristics considerations for the deep underwater muon and neutrino detection system

Description

The results of an investigation of the characteristics of photomultipliers for the Deep Underwater Muon and Neutrino Detection (DUMAND) System are discussed. The pulse-height resolution, the afterpulsing phenomena and the gain sensitivity to the ambient magnetic field have been determined for large photocathode area photomultipliers. Furthermore, the transient time difference, the single photoelectron time spread, and the collection and photocathode quantum efficiency uniformity as a function of the position of the photocathode sensing area have been reviewed. Finally, an attempt has been made to estimate the photomultiplier reliability and its lifetime

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS., PC A02/MF A01.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
23 p.
Report number
LBL--10547

Conference

Title
Deep underwater muon and neutrino detection signal processing workshop.
Dates
11 - 16 Feb 1980.
Place
Honolulu, HI, USA.

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
11559822
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
MEASURING METHODS; MUONS; NEUTRINO DETECTION; PHOTOMULTIPLIERS; PULSE ANALYZERS; RELIABILITY; SIGNALS; TARGETS; UNDERWATER
Descriptors DEC
ELECTRONIC EQUIPMENT; ELEMENTARY PARTICLES; FERMIONS; LEPTONS; LEVELS; PHOTOTUBES; RADIATION DETECTION

Optional Information

Secondary number(s)
CONF-800240--2.