Published 2013 | Version v1
Miscellaneous

Assessment of Structural Integrity of the Pool Door for Research Reactor

Creators

  • 1. Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

Description

The principal function of the pool door, which is located between the reactor pool and the service pool, is to separate the reactor pool from the service pool for the maintenance and the removal of the equipment either in the reactor pool or in the service pool. Therefore, the pool door should maintain its strength and stiffness against the external loads and it prevents the leakage of pool water when it is installed in the pool gate. The structural integrity and leak-tightness are critical design requirements. In this study, various loads are considered such as dead load, fluid static load and fluid dynamic load due to seismic event (SSE) to verify the structural integrity of the pool door

Part of:
Joint IGORR 2013 and IAEA Technology Meeting

Additional details

Publishing Information

Publisher
IGORR
Imprint Place
Daejeon (Korea, Republic of)
Imprint Title
Joint IGORR 2013 and IAEA Technology Meeting
Imprint Pagination
[1 CD-ROM]
Journal Page Range
[3 p.]

Conference

Title
Joint IGORR 2013 and IAEA Technology Meeting
Dates
13-18 Oct 2013
Place
Daejeon (Korea, Republic of)

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
45103512
Subject category
S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
DESIGN; FLEXIBILITY; FLUID MECHANICS; LEAKS; MAINTENANCE; REMOVAL; RESEARCH REACTORS; SEISMIC EVENTS
Descriptors DEC
MECHANICAL PROPERTIES; MECHANICS; REACTORS; RESEARCH AND TEST REACTORS; TENSILE PROPERTIES

Optional Information