Published 1992 | Version v1
Journal article

Neutron dosimetry. Performance of bubble dosemeters. Comparison with other usual radiation detectors

Creators

  • 1. Institut National des Sciences et Techniques Nucleaires (INSTN), Centre d'Etudes de Saclay, 91 - Gif-sur-Yvette (France)

Description

Based on the bubble chamber principle, the pen bubble dosemeters are composed of a gel or a polymer in which Freon micro droplets have been dispersed. Upon neutron interaction, the droplets vaporize. The bubble counting gives the dose equivalent measurement. The first part of this report describes the principle and the main characteristics of these detectors. The use of detectors type BD 100 and BD 100 RS and the results about the perfecting of different reader devices are presented in the second part. The third part is about the calibration of these detectors with Am-Be sources as also the calibration of usual detectors: Cramal, Dineutron, rem counter, TLD600+ TLD700 and dosemeter film

Additional details

Additional titles

Original title (French)
Dosimetrie des neutrons. Performance des dosimetres a bulles. Comparaison avec d'autres detecteurs usuels

Publishing Information

Journal Title
Rayonnements Ionisants, Techniques de Mesures et de Protection
Journal Volume
21
Journal Issue
2
Journal Page Range
p. 15-30.
ISSN
0397-9210
CODEN