Published July 1, 2014 | Version v1
Journal article

Utilization of highly purified single wall carbon nanotubes dispersed in polymer thin films for an improved performance of an electrochemical glucose sensor

  • 1. Center for Materials Research, Norfolk State University, 555 Park Avenue, Norfolk, VA 23504 (United States)
  • 2. Molecular Toxicology Laboratory, Center for Biotechnology and Biomedical Sciences, Norfolk State University, 700 Park Avenue, Norfolk, VA 23504 (United States)
  • 3. Luna Innovations, Inc., 706 Forest St., Suite A, Charlottesville, VA 22902 (United States)
  • 4. RICE University, 6100 Main St, Houston, TX 77251 (United States)

Description

In this work we report the improved performance an electrochemical glucose sensor based on a glassy carbon electrode (GCE) that has been modified with highly purified single wall carbon nanotubes (SWCNTs) dispersed in polyethyleneimine (PEI), polyethylene glycol (PEG) and polypyrrole (PPy). The single wall carbon nanotubes were purified by both thermal and chemical oxidation to achieve maximum purity of ∼ 98% with no damage to the tubes. The SWCNTs were then dispersed by sonication in three different organic polymers (1.0 mg/ml SWCNT in 1.0 mg/ml of organic polymer). The stable suspension was coated onto the GCE and electrochemical characterization was performed by Cyclic Voltammetry (CV) and Amperometry. The electroactive enzyme glucose oxidase (GOx) was immobilized on the surface of the GCE/(organic polymer–SWCNT) electrode. The amperometric detection of glucose was carried out at 0.7 V versus Ag/AgCl. The GCE/(SWCNT–PEI, PEG, PPY) gave a detection limit of 0.2633 μM, 0.434 μM, and 0.9617 μM, and sensitivities of 0.2411 ± 0.0033 μA mM−1, r2 = 0.9984, 0.08164 ± 0.001129 μA mM−1, r2 = 0.9975, 0.04189 ± 0.00087 μA mM−1, and r2 = 0.9944 respectively and a response time of less than 5 s. The use of purified SWCNTs has several advantages, including fast electron transfer rate and stability in the immobilized enzyme. The significant enhancement of the SWCNT modified electrode as a glucose sensor can be attributed to the superior conductivity and large surface area of the well dispersed purified SWCNTs. - Highlights: • Purification method employed here use cheap and green oxidants. • The method does not disrupt the electronic structure of nanotubes. • This method removes nearly < 2% metallic impurities. • Increases the sensitivity and performance of glassy carbon electrode • This system can detect as low as 0.066 μM of H2O2 and 0.2633 μM of glucose

Availability note (English)

Available from http://dx.doi.org/10.1016/j.msec.2014.04.009

Additional details

Identifiers

DOI
10.1016/j.msec.2014.04.009;
PII
S0928-4931(14)00201-X;

Publishing Information

Journal Title
Materials Science and Engineering. C, Biomimetic Materials, Sensors and Systems
Journal Volume
40
Journal Page Range
p. 299-307
ISSN
0928-4931

Optional Information

Copyright
Copyright (c) 2014 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.