Published September 1996 | Version v1
Journal article

Determination of zeta calibration constant against a corning dosimeter glass of 36 ppm natural uranium using age-standard apatites

  • 1. Shillong College, Meghalaya (India)
  • 2. Arya Vidyapith College, Guwahati (India)
  • 3. Tezpur Univ., Tezpur (India)
  • 4. Gauhati Univ., Guwahati (India). Dept. of Geological Sciences

Description

Zeta calibration of standard dosimeter glass of 36 ppm natural uranium (corning) has been made against age standard apatite minerals from Mt. Dromedary complex (98.7 ± 0.6) Ma and Fish Canyon Tuff (27.77 ± 0.08) Ma. The result is ζ = 1112± 21. (author). 11 refs., 2 tabs

Additional details

Publishing Information

Journal Title
Indian Journal of Physics. Part A
Journal Volume
70
Journal Issue
5
Journal Page Range
p. 655-658.
ISSN
0252-9262
CODEN
INJADP