Reasons for the variation in patient doses from chest radiography procedure were investigated by assessing entrance skin doses from kerma-area product measurements. Data were collected from seven x-ray tubes in five hospitals involving 259 adult patients. The third quartile value was 0.81 mGy compared to general reference level of 0.30 mGy. The applied tube potential was main contributor to patient dose variation. If department use at least 90 k Vp, the mean entrance surface dose would be reduced ut to factor six. Modification of departmental procedure is correct approach for dose reduction in diagnostic radiology. (author)
Availability note (English)
Available from INIS in electronic form; Also available from Institute of Nuclear Sciences VINCA, Library, PO Box 522, 11001 Belgrade, Serbia and MontenegroAbstract (Serbian)
Nivoi izlozenosti pacijenta tokom radiografije pluca analizirani su merenjem proizvoda kerme i povrsine (KAP) za ukupno 259 odraslih pacijenata, u pet zdravstvenih ustanova. Koristeci izmerene vrednosti i podatke o radiografskoj tehnici izracunata je doza na povrsini koze pacijenta (ESD) za svakog pacijenta. Srednja vrednost KAP bila je 0.76 (0.22-1.88) Gy·cm2 a srednja vrednost ESD 0,78 (0.23-1.88) mGy. Za referntni nivo odabrana je vrednost treceg kvartila distribucije izmerenih vrednosti, sto iznosi 0.81 mGy. Osnovni uzrok varijacije pacijentnih doza nalazi se u primenjenoj radiografskoj tehnici: visokom naponu, rastojanju fokus-film i koriscenoj kombinaciji film-poja civacka folija. Smanjenje doza moze se postici korekcijom radioloske prakse: povecanjem napona i faktora pojacanja kombinacija film-pojacivacka folija u skladu sa telesnom masom pacijenta. (autor)Files
37121852.pdf
Files
(91.7 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:81373dc7654e7cf917957b1d9023ae14
|
91.7 kB | Preview Download |
Additional details
Additional titles
- Original title (Serbian)
- Dozimetrijski aspekti radiografije pluca
Publishing Information
- Publisher
- Society for Electronics, Telecommunications, Computers, Automation and Nuclear Engineering. Section for Nuclear Techniques and Technology
- Imprint Place
- Beograd (Serbia and Montenegro)
- Imprint Pagination
- 4 p.
- Report number
- INIS-RS--0225
Conference
- Title
- Society for Electronics, Telecommunications, Computers, Automation, and Nuclear Engineering
- Original Conference Title
- ETRAN 2004: 48. Konferencija za elektroniku, telekomunikacije, racunarstvo, automatiku i nuklearnu tehniku
- Acronym
- 48. Conference - ETRAN 2004
- Dates
- 6-10 Jun 2004
- Place
- Cacak (Serbia and Montenegro)
INIS
- Country of Publication
- Serbia
- Country of Input or Organization
- Serbia
- INIS RN
- 37121852
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Resource subtype / Literary indicator
- Conference, Numerical Data
- Descriptors DEI
- AMPLIFICATION; BIOMEDICAL RADIOGRAPHY; DOSIMETRY; ELECTRIC POTENTIAL; EXPERIMENTAL DATA; FOCUSING; KERMA; LUNGS; MEDICAL ESTABLISHMENTS; PATIENTS; RADIATION DOSE DISTRIBUTIONS; RADIATION DOSE UNITS; SKIN; SPACE DEPENDENCE; X-RAY TUBES
- Descriptors DEC
- BODY; DATA; DIAGNOSTIC TECHNIQUES; ELECTRON TUBES; EQUIPMENT; INFORMATION; MEDICINE; NUCLEAR MEDICINE; NUMERICAL DATA; ORGANS; RADIOLOGY; RESPIRATORY SYSTEM; UNITS; X-RAY EQUIPMENT
Optional Information
- Notes
- 11 ref., 2 figs., 4 tabs.
- Secondary number(s)