Published December 2013 | Version v1
Journal article

Radon prevention coating in hot and humid environment

  • 1. Key Laboratory of Defensive Discipline on Nuclear Wastes and Environmental Safety, Southwest University of Science and Technology, Mianyang (China)
  • 2. Key Laboratory of Treatment and resource of Solid Wastes of Ministry of Education, Southwest University of Science and Technology, Mianyang (China)

Description

The radon prevention performance of a new self-made radon prevention coating was researched in the radon contamination provided by the releasing radon modules. With coating thickness of 0.8 mm, the radon mitigation efficiency in 1# radon module concentration is optimal when the addition of defoaming agent is 0.3% (mass fraction). The radon mitigation efficiency increases with the coating thickness when the defoaming agent of 0.3% is added, but the radon mitigation efficiency tends to be stable as the coating thickness is more than 2.0 mm. The radon mitigation efficiency of radon prevention coating appended precipitated barium sulphate decreases obviously, and the addition of ash calcium, white cement and gesso don't decrease radon mitigation efficiency. The addition of white cement and gesso addition affects the radon prevention stability, while radon mitigation efficiency of radon prevention coating with ash calcium keeps a good performance. Under the hot and humid environment, the radon prevention coating still has good radon mitigation efficiency in 2# radon module concentration. (authors)

Additional details

Publishing Information

Journal Title
Atomic Energy Science and Technology
Journal Volume
47
Journal Issue
12
Journal Page Range
p. 2384-2388
ISSN
1000-6931

Optional Information

Notes
5 figs., 3 tabs., 9 refs.