Published January 1991 | Version v1
Journal article

Reduction of volume of BWR plant radioactive wastes by operating condensate demineralizers without regeneration

  • 1. Tokyo Electric Power Co., Inc. (Japan)

Description

Since chemical regeneration of condensate demineralizers produces a large quantity of radioactive liquid wastes, reducing the volume of such wastes has become a significant concern. In Japanese Improvement and Standardization BWR's, by installing a prefilter upstream from the condensate demineralizer, and improving construction materials and method of controlling water chemistry, the crud and ion load on the condensate demineralizer has been reduced. Since non-regenerated operation of the condensate demineralizer has been devised and tried on the N0.2 Unit of the Fukushima Daini Nuclear Power Station (2F-2) with variable resin measurement during every scheduled outage and each fuel cycle. The result has been a reduction of the number of drums to be disposed of to 1/5 the previous number. (author)

Additional details

Publishing Information

Journal Title
Journal of Nuclear Science and Technology (Tokyo)
Journal Volume
28
Journal Issue
1
Series
J. Nucl. Sci. Technol. (Tokyo).
Journal Page Range
59-65
ISSN
0022-3131
CODEN
JNSTA