Published November 1975 | Version v1
Journal article

Radioimmune assay of heterologous serum γ-globulin in patients receiving rabbit antihuman thymocyte globulin

Description

A radioimmune assay (RIA) method for detecting heterologous serum rabbit γ-globulin (RG) and antibody to this protein is described. The methodology is used for monitoring serum levels of rabbit globulin in patients receiving rabbit ATG (RATG). In 7 cardiac recipients receiving RATG, maximum serum levels of RG were achieved 1 to 3 days after administration of final dose. RG half-life subsequent to peak serum levels was rapid (X = 36 hr) in 4 patients and prolonged (X = 18 days) in 3 patients. Patient antibody to rabbit γ-globulin was detectable only in those patients with short RG half-life. Antirabbit antibody titers in these patients were extremely low and barely detectable by RIA

Additional details

Additional titles

Augmented title (English)
"1"2"5I tracer technique

Publishing Information

Journal Title
Transplantation
Journal Volume
20
Journal Issue
5
Series
Transplantation.
Journal Page Range
393-398