Published March 1994 | Version v1
Journal article

Conceptual design of the 800 MeV multi-purpose proton accelerator

  • 1. Kyoto Univ., Uji (Japan). Inst. for Chemical Research

Description

A multi-purpose accelerator complex which accelerates protons up to 800 MeV is proposed. It consists of multi-step linear accelerators and two synchrotrons. The linac section contains a 433 MHz RFQ linac, a 433 MHz and a 1300 MHz Alvarez linacs and a 1300 MHz DAW linac. One of the synchrotrons is a weak current 250 MeV medical synchrotron and the other is a high current 800 MeV FFAG synchrotron. Main purposes of the accelerator are proton therapy, neutron and meson physics. (author)

Additional details

Publishing Information

Journal Title
Bulletin of the Institute for Chemical Research, Kyoto University
Journal Volume
72
Journal Issue
1
Journal Page Range
p. 69-75.
ISSN
0023-6071
CODEN
BICRAS