Published November 1985 | Version v1
Report Restricted

Program for field validation of the Synthetic Aperture Focusing Technique for Ultrasonic Testing (SAFT UT). Final report

Description

This final report describes work performed by Southwest Research Institute for the Nuclear Regulatory Commission (NRC) in fulfillment of NRC Contract No. NRC-04-77-145: ''Program for Field Validation of the Synthetic Aperture Focusing Technique for Ultrasonic Testing (SAFT UT).'' The purpose of the project was to validate the effectiveness of SAFT UT as a nondestructive examination technique for nuclear power and other related industries. SAFT UT is an ultrasonic imaging method for accurate measurement of the spatial location and extent of acoustically reflective surfaces (flaws) contained in objects such as structural components and weldments in nuclear power reactor systems. The increased measurement accuracy offered by SAFT, when compared with that provided by measurement methods now in use, will improve the reliability of flaw severity assessment with resultant safety and economic benefits to the nuclear power industry. This report presents a comprehensive discussion of the work accomplished in evaluating the performance capabilities of the developed SAFT UT inspection system. Inspection results obtained using both 0-degree longitudinal and angle-beam operating modes are presented. These results include laboratory and nuclear power plant field site examinations on a variety of defect types contained within carbon and stainless steel flat plate and cylindrical test specimens or components. The SAFT UT processed data flaw images are evaluated by comparing them to results obtained from destructive sectioning or by using flaw fabrication data which predicted actual flaw depth, orientation and size. On the basis of these evaluations, conclusions are presented which summarize the performance capabilities of the SAFT UT inspection technique. 116 figs

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS, PC A08/MF A01 - GPO as TI86900627.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
170 p.
Report number
NUREG/CR--4078

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
17062614
Subject category
S42: ENGINEERING;
Descriptors DEI
CALIBRATION; IMAGE PROCESSING; INSPECTION; PERFORMANCE; PIPES; REACTOR VESSELS; RESEARCH PROGRAMS; SENSITIVITY; ULTRASONIC TESTING; VERIFICATION; WELDED JOINTS
Descriptors DEC
ACOUSTIC TESTING; CONTAINERS; JOINTS; MATERIALS TESTING; NONDESTRUCTIVE TESTING; TESTING