Published 2004 | Version v1
Journal article

Dose evaluation in criticality accident conditions using transient critical facilities fueled with a fissile solution

  • 1. Japan Atomic Energy Res. Inst., Shirakata-Shirane 2-4, Tokai-mura, Ibaraki-ken 319-1195 (Japan)

Description

Neutron dose measurement and evaluation techniques in criticality accident conditions using a thermo luminescence dosemeter (TLD) was studied at the Transient Experiment Critical Facility (TRACY) of Japan Atomic Energy Research Inst. (JAERI). In the present approach, the absorbed dose is derived from the ambient dose equivalent measured with a TLD, using the appropriate conversion factor given by computation. Using this technique, the neutron dose around the SILENE reactor of the Inst. for Radioprotection and Nuclear Safety (IRSN) of France was measured in the Accident Dosimetry Intercomparison Exercise (June 10-21, 2002) organized by OECD/NEA and IRSN. In this exercise, the gamma dose was also measured with a TLD. In this report, measurements and evaluation results at TRACY and SILENE are presented. (authors)

Availability note (English)

Available from doi: http://dx.doi.org/10.1093/rpd/nch348

Additional details

Identifiers

Publishing Information

Journal Title
Radiation Protection Dosimetry
Journal Volume
110
Journal Issue
1-4
Journal Page Range
p. 483-486
ISSN
0144-8420

Conference

Title
9. Symposium on Neutron Dosimetry - Advances in nuclear particle dosimetry for radiation protection and medicine
Dates
28 Sep - 3 Oct 2003
Place
Delft (Netherlands)

Optional Information

Notes
4 refs.